<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HPLC Testing &#187; Beta Thalassemia</title>
	<atom:link href="http://www.hplctesting.com/tag/beta-thalassemia/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.hplctesting.com</link>
	<description>Tosoh Bioscience Journal of Advancements in HPLC Testing</description>
	<lastBuildDate>Wed, 21 Sep 2011 21:40:11 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>HPLC Testing Video Shows Switching from HbA1c to Beta-thalassemia Testing Mode on Tosoh G7 HPLC Analyzer</title>
		<link>http://www.hplctesting.com/hplc-testing-video-hba1c-to-beta-thalassemia-testing-tosoh-g7-hplc-analyzer/</link>
		<comments>http://www.hplctesting.com/hplc-testing-video-hba1c-to-beta-thalassemia-testing-tosoh-g7-hplc-analyzer/#comments</comments>
		<pubDate>Wed, 20 May 2009 04:18:16 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Beta Thalassemia]]></category>
		<category><![CDATA[HPLC]]></category>

		<guid isPermaLink="false">http://www.hplctesting.com/?p=74</guid>
		<description><![CDATA[
HPLC Testing Video: Switching from HbA1c to Beta-thalassemia testing mode is an intuitive process on the Tosoh G7 HPLC Analyzer. Tosoh has released an instructional web video that explains the process as well as some of the features and benefits of the G7 HPLC Analyzer.
The Tosoh G7 Automated HPLC Analyzer facilitates both hemoglobin A1c and [...]]]></description>
			<content:encoded><![CDATA[<p><object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" width="425" height="344" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="data" value="http://www.youtube.com/v/LoevXX36lN8&amp;hl=en&amp;fs=1&amp;rel=0" /><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/LoevXX36lN8&amp;hl=en&amp;fs=1&amp;rel=0" /><param name="allowfullscreen" value="true" /><embed type="application/x-shockwave-flash" width="425" height="344" src="http://www.youtube.com/v/LoevXX36lN8&amp;hl=en&amp;fs=1&amp;rel=0" allowscriptaccess="always" allowfullscreen="true" data="http://www.youtube.com/v/LoevXX36lN8&amp;hl=en&amp;fs=1&amp;rel=0"></embed></object><br />
HPLC Testing Video: Switching from HbA1c to <a title="Beta Thalassemia Testing Mode on G7 HPLC Analyzer" href="http://betathalassemiatesting.com" target="_self">Beta-thalassemia testing</a> mode is an intuitive process on the Tosoh G7 HPLC Analyzer.<span> </span>Tosoh has released an instructional web video that explains the process as well as some of the features and benefits of the G7 HPLC Analyzer.<span id="more-74"></span></p>
<p>The <a title="HPLC Testing on G7 HPLC Analyzer" href="http://www.diagnostics.us.tosohbioscience.com/Products/G7/" target="_self">Tosoh G7 Automated HPLC Analyzer </a>facilitates both hemoglobin A1c and Beta-thalassemia testing to provide laboratories with the full patient profile.<span> </span>The Beta-thalassemia program quantifies hemoglobins F and A2, which are used in screening for Beta-thalassemia. In addition, the Beta-thalassemia testing program is used for presumptive identification of hemoglobins S, C and D and for screening for other hemoglobinopathies.</p>
<p>HPLC is the preferred methodology for hemoglobinopathy screening.<span> </span>Since the G7 can be used for both hemoglobin A1c and Beta-thalassemia testing, it is essentially 2 instruments in 1.</p>
<p>NGSP certified, the G7 provides time and labor-savings with primary tube sampling, automated cap piercing and positive sample identification. Most importantly, with less than 2% CV’s, the G7 offers an extremely high level of both precision and accuracy.</p>
<div id="attachment_78" class="wp-caption alignnone" style="width: 310px"><a href="http://www.betathalassemiatesting.com"><img class="size-medium wp-image-78" title="HPLC Testing: Beta thalassemia Mode on G7 HPLC Analyzer" src="http://www.hplctesting.com/wp-content/uploads/2009/05/hplctesting_betathalassemia-300x200.jpg" alt="HPLC Testing: Beta thalassemia Mode on G7 HPLC Analyzer" width="300" height="200" /></a><p class="wp-caption-text">HPLC Testing: Beta thalassemia Mode on G7 HPLC Analyzer</p></div>
<p>Switching between the hemoglobin A1c and Beta-thalassemia testing programs is very easy, simple and fast. Just remove the hemoglobin A1c reagents, replace them with the Beta-thalassemia reagents, and the G7 HPLC Analyzer will do the rest.<span> </span>Once the buffers and column have been changed, the system is automatically primed and is ready to perform analysis within minutes.</p>
<p><span>Tosoh Bioscience is a world leader in the development of diagnostic products for HPLC and immunoassay testing.<span> </span>For more information, contact Tosoh Bioscience at (800) 248-6764 or visit </span><span><a href="http://www.diagnostics.us.tosohbioscience.com/"><span>http://www.diagnostics.us.tosohbioscience.com</span></a></span></p>
<p><!--EndFragment--></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hplctesting.com/hplc-testing-video-hba1c-to-beta-thalassemia-testing-tosoh-g7-hplc-analyzer/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>HPLC Testing: G7 HPLC Analyzer Tests Both HbA1c and Beta Thalassemia</title>
		<link>http://www.hplctesting.com/hplc-testing-g7-hplc-analyzer-tests-hba1c-and-beta-thalassemia/</link>
		<comments>http://www.hplctesting.com/hplc-testing-g7-hplc-analyzer-tests-hba1c-and-beta-thalassemia/#comments</comments>
		<pubDate>Wed, 29 Apr 2009 01:37:10 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[G7 HPLC Analyzer]]></category>
		<category><![CDATA[Beta Thalassemia]]></category>
		<category><![CDATA[hba1c]]></category>
		<category><![CDATA[HPLC Testing]]></category>
		<category><![CDATA[tosoh]]></category>

		<guid isPermaLink="false">http://www.hplctesting.com/?p=52</guid>
		<description><![CDATA[
(April 28, 2009) … HPLC Testing Report: Tosoh’s G7 HPLC Analyzer tests both beta thalassemia and hemoglobin A1c in one compact benchtop analyzer.  Features include: stable HbA1c results in 2.2 minutes, β-thalassemia results in less than 8 minutes, quantification of HbF and HbA2, multi-functional STAT sample position, presumptive ID of hemoglobinopathies, inventory management system, [...]]]></description>
			<content:encoded><![CDATA[<p><object width="445" height="364" data="http://www.youtube.com/v/nuVYsDCT1Ns&amp;hl=en&amp;fs=1&amp;rel=0&amp;border=1" type="application/x-shockwave-flash"><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/nuVYsDCT1Ns&amp;hl=en&amp;fs=1&amp;rel=0&amp;border=1" /><param name="allowfullscreen" value="true" /></object><br />
(April 28, 2009) … HPLC Testing Report: Tosoh’s G7 HPLC Analyzer tests both beta thalassemia and hemoglobin A1c in one compact benchtop analyzer.  Features include: stable HbA1c results in 2.2 minutes, β-thalassemia results in less than 8 minutes, quantification of HbF and HbA2, multi-functional STAT sample position, presumptive ID of hemoglobinopathies, inventory management system, user-friendly software, compact size, NGSP certified.</p>
<p>For more information, go to <a href="http://www.diagnostics.us.tosohbioscience.com/Products/G7/">G7 HPLC Analyzer </a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.hplctesting.com/hplc-testing-g7-hplc-analyzer-tests-hba1c-and-beta-thalassemia/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

